Applying configuration changes
Changes to the management plane and to an availability zone are values on the superphenix-operator release. Add them to the values file, then upgrade the release. Argo CD applies the applications.
Management plane
Management applications (the console, the API, Kratos, Permify, and PostgreSQL) are set under management.systemConfiguration.
management:
systemConfiguration:
apps:
superphenix-api:
values:
config:
userSettings:
userIsActiveOnCreate: true
The pages under Configuring the management components detail all the settings available in here.
Argo CD itself is installed by the operator chart, so its settings live beside management, under config.argocd.values.
Availability zone
Applications that run on an availability zone are set under clusters.<code>.systemConfiguration. The key is the AZ code: local when the zone runs on the management cluster, and the code you chose in Add an availability zone otherwise.
clusters:
paris-1:
systemConfiguration:
apps:
rook-local-cluster:
values:
ingress:
dashboard:
host:
name: ceph.admin.example.org
Lifecycle
lifecycle decides whether an upgrade is applied on its own. The same three switches exist for the management plane (management.lifecycle) and for each availability zone (clusters.<code>.lifecycle). All three default to false. Configure a cluster is the same list on an availability-zone entry.
management:
lifecycle:
pause: false
manual: false
cleanupOnDeletion: false
clusters:
paris-1:
lifecycle:
pause: false
manual: false
cleanupOnDeletion: false
| Field | Effect |
|---|---|
pause |
Synchronization stops. Automatic and manual sync both wait until you set it back to false. The cluster is reported as Paused. |
manual |
Automatic sync is off. The applications stay as they are until you sync them in Argo CD, or set this back to false. |
cleanupOnDeletion |
Removing this cluster also deletes the applications it installed. Leave it false unless you intend to remove the stack. |
Set manual to true when the values should be saved and the applications left untouched until you sync them. Set pause to true when nothing should sync, including a sync you start by hand. Set the switch back to false and upgrade again to resume.
Upgrade the release
Add the keys to the values file you already pass for this release, then upgrade:
OPERATOR_VERSION="$(curl -fsSL -o /dev/null -w '%{url_effective}' https://github.com/super-phenix/superphenix/releases/latest | sed 's#.*/v##')"
helm upgrade superphenix-operator \
"oci://ghcr.io/super-phenix/charts/superphenix-operator:${OPERATOR_VERSION}" \
--namespace superphenix-system \
-f values.yaml
Replace OPERATOR_VERSION by your vesion of Superphenix or use the latest to upgrade your version.
Helm merges that file with the chart defaults. A later upgrade still needs the same -f file, or the keys you added are dropped.
With pause and manual left at false, wait until the application you changed is Synced and Healthy in Argo CD before you test. While manual is true, sync that application yourself. While pause is true, the sync waits until you turn it off. Accessing Superphenix covers opening Argo CD.